Using SDL_INIT_JOYSTICK implies SDL_INIT_EVENTS which installs a signal
handler for SIGINT and SIGTERM. There will be a way to prevent this in
2.0.4 but for now we'll need to handle SDL_QUIT.
- Simplified the locking mechanism when controllers were updated
- Reloaded the config of the controls instead of re-initialising the control plugins
- Fixed controls being unresponsive after the Refresh button was pressed
- Disables the hotkeys while the controller config is open
I'm not sure when this nonsense of forcing locking the mutex when it's
already taken should have ever taken effect, but let's be thankful it
isn't now. That was a badly worded sentence.
Initialize now just takes the handle directly. Reinitialize is added because it is much more straightforward in comparison to doing the Shutdown-Initialize manually.
Yes, this is a fancy new feature, but our Wayland support was
particularly bitrotten, and ideally this would be handled by a platform
layer like SDL. If not, we can always add this back in when GLInterface
has caught up. We might be able to even support wxWidgets and GL
together with subsurfaces!
It was broken by e15ec56bf0 because it wasn't deemed important. However chances are people will eventually start using Dolphin on that configuration, so we shouldn't frivolously drop compatibility without good reason.